How to Start an IVF Centre in India: ART Act Registration, IVF Lab Design & Cost (2026)
November 12, 2026How to Start a Dialysis Centre in India: Licences, RO Water, Layout & Cost (2026 Guide)
November 12, 2026How to Start a Radiology & Imaging Centre in India: AERB, PCPNDT, Room Design & Cost (2026)
An imaging centre is the one healthcare facility where the building itself is part of the safety system. Lead-lined walls, the position of the CT gantry, the 5-gauss line around an MRI magnet: get these wrong on paper and you either fail approval or pay to break walls later.
This guide covers what founders need to decide before signing an equipment order: which modalities to offer, which regulator approves each one, how big the rooms must be, and what it all costs in 2026. If you also plan a pathology lab, read our broader guide on starting a diagnostic centre in India.
In this guide ▾
- Each modality has its own regulator: X-ray and CT need AERB approval through eLORA, ultrasound needs PCPNDT registration, and MRI needs no AERB licence but is the hardest room to engineer.
- CT needs an approved RSO first: for CT and interventional radiology, AERB requires an approved Radiological Safety Officer before you apply for the licence.
- Get the layout right before civil work: AERB reviews a scaled layout showing walls, shielding, equipment position and the occupancy around the room.
- Buy only AERB type-approved equipment from authorised suppliers. Quality assurance tests and personnel dose monitoring continue for as long as you operate.
- Indicative 2026 capex: about ₹40–90 lakh for X-ray plus ultrasound, ₹1.5–3.5 crore with CT, and ₹8 crore+ for a full centre with a new 1.5T MRI.
Step 1: Choose your modality mix
Start from referral demand in your catchment, not from the equipment brochure. Most standalone centres open with digital X-ray and ultrasound, add CT once referral volumes justify it, and add MRI last.
| Modality | Regulatory approval | Space to plan for | Indicative equipment cost |
|---|---|---|---|
| Digital X-ray (DR/CR) | AERB registration via eLORA | About 18–20 m² room plus console | ₹15–35 lakh |
| Ultrasound / colour Doppler | PCPNDT registration with the district Appropriate Authority | 10–12 m² room with attached toilet | ₹8–40 lakh |
| Mammography | AERB registration via eLORA | About 12–15 m² | ₹40 lakh–1.2 crore |
| CT (16–128 slice) | AERB licence, plus an approved RSO | Gantry room of 25–30 m², plus control and equipment rooms | ₹1–3.5 crore (new) |
| MRI (1.5T) | No AERB licence (non-ionising); clinical establishment registration, structural and RF engineering | 35–50 m² magnet room, plus console and technical rooms | ₹5–8 crore (new) |
Step 2: AERB licensing through eLORA (X-ray, CT, mammography)
All institutions using medical diagnostic X-ray equipment must obtain consent from the Atomic Energy Regulatory Board (AERB) before using it on patients. Applications are made online through eLORA (e-Licensing of Radiation Applications). The sequence is:
- Register your institute on eLORA.
- Declare your equipment. Only AERB type-approved models from authorised suppliers can be declared.
- Submit the room layout. This is a scaled drawing (1:50) showing room dimensions, wall thickness and material, equipment and couch position, control console, doors and windows, and what occupies the spaces around the room. AERB publishes model layouts, and following one simplifies review.
- Get an RSO approved (CT and interventional radiology). The nominee registers as a Radiation Professional on eLORA. A radiologist, or a technologist with relevant CT or cath-lab experience, is typically eligible.
- Install and run QA tests. Installation is done by the authorised supplier, followed by quality assurance tests.
- Apply for the licence or registration. Once approved, the certificate is downloaded from your eLORA account.
AERB does not currently charge a licence or processing fee for these consents, and diagnostic X-ray licences are commonly valid for five years. Renew through eLORA before expiry. The ongoing obligations are just as important: personnel dose monitoring (TLD badges) for radiation workers, periodic QA tests, warning lights and signage at room entrances, and keeping your registration current when equipment changes.
Step 3: PCPNDT registration for ultrasound
Any centre with an ultrasound machine must register under the Pre-Conception and Pre-Natal Diagnostic Techniques (PCPNDT) Act with the district Appropriate Authority before installing or using the machine. Inspectors check these points closely:
- Display the registration certificate and a clear notice that sex determination is not done and is a punishable offence.
- Complete a Form F for every pregnant woman scanned, and preserve records for the prescribed period (at least two years).
- Allow only qualified, registered doctors to perform scans, and keep your list of registered persons and machines updated.
- Report any purchase, sale or transfer of an ultrasound machine to the authorities.
- Renew the registration before it expires. It is valid for five years.
Clinical establishment registration, BMW authorisation, fire compliance and local licences apply on top of AERB and PCPNDT. See our checklist of licences required to open a hospital in India, or let our licensing team run the filings for you.
Step 4: Room design and shielding
AERB’s earlier safety code set fixed minimums: at least 18 m² for a general radiography room, at least 25 m² for the CT gantry room, and no side shorter than 4 m. The current code asks instead for an “appropriate area” for safe movement and positioning, backed by AERB’s model layouts. Most planners still treat the older figures as practical minimums. They also keep the CT control console in a separate room adjoining the gantry room, as the code requires.
Shielding principles
- Wall, floor and ceiling shielding is calculated for your equipment and workload, then built in brick, concrete or lead lining. The thickness must appear on the layout you submit.
- Doors and the control-room viewing window need a lead equivalent that matches the walls.
- Point the primary beam (the chest stand wall) away from doors, waiting areas and occupied rooms next door.
- In rented premises, check who occupies the floor above, the floor below and the space next door. It changes your shielding.
MRI is a different engineering problem
- An RF-shielded cage around the magnet room, with a filtered penetration panel for services.
- Control of the 5-gauss line so that it stays inside restricted areas, with zone-based access for patients and staff.
- A quench pipe venting to the outside, a chiller and helium management, and a dedicated technical room.
- Floor loading and vibration checks, plus a delivery route (often a knock-out panel) for a magnet weighing several tonnes.
| Room | Planning benchmark | Key notes |
|---|---|---|
| General X-ray | ≥18 m², no side under 4 m | Lead-lined door, viewing window, warning light |
| CT suite | Gantry room ≥25 m², plus control and equipment rooms | Separate control room, patient prep and contrast observation nearby |
| Ultrasound | 10–12 m² | Attached toilet, privacy, PCPNDT signage |
| Mammography | 12–15 m² | Privacy, female-staff workflow, changing cubicle |
| MRI | 35–50 m² magnet room | RF cage, quench pipe, technical room, zoning |
Our civil, MEP and fire turnkey team and facility layout team coordinate shielding, HVAC and power with the equipment vendor’s site requirements.
Shielding is cheapest when it is part of the structure. Get the shielding calculation and AERB layout prepared before civil work starts, especially for CT. Retrofitting lead after finishes costs more and delays the licence.
Step 5: Patient flow and staffing
- Flow: reception and billing lead to a waiting area, then changing cubicles, the scan room, and an exit. Keep pregnant patients and paediatric cases out of radiation-controlled corridors.
- CT contrast: provide a preparation and observation bay next to the CT room with a crash cart, oxygen and suction, plus nursing cover.
- Reporting: a quiet reporting room with PACS workstations. Teleradiology can cover night reporting, but plan for on-site clinical cover during contrast studies.
- Team: radiologist (MD, DNB or DMRD), qualified radiographers or medical imaging technologists, an approved RSO for CT, a nurse, and front-desk and billing staff.
Recruiting a radiologist is often the deciding factor in Tier-2 and Tier-3 towns. Our HR mobilisation team can help you plan for it early.
Planning a CT or MRI centre?
Get a modality plan, room layout and AERB/PCPNDT roadmap for your site.
What does it cost to start an imaging centre in 2026?
| Setup | Typical area | Indicative capex (excl. property) |
|---|---|---|
| X-ray + ultrasound | 800–1,500 sq ft | ₹40–90 lakh |
| X-ray + ultrasound + CT | 2,000–3,500 sq ft | ₹1.5–3.5 crore |
| Full imaging (adds 1.5T MRI, mammography) | 4,000–6,500 sq ft | ₹8–14 crore |
Budget items that are often missed include a transformer or electrical load upgrade and UPS for CT and MRI, precision air-conditioning for equipment rooms, PACS/RIS licences, annual maintenance contracts after the warranty, and six months of working capital.
See our guides on funding a healthcare project and insurance and PM-JAY empanelment, or talk to our equipment procurement team about new versus refurbished systems.
Launch checklist
- Map referral demand in your catchment and fix the modality mix.
- Shortlist a site: ground floor, structural capacity, power, parking and neighbours. Our site selection team can assess options.
- Select AERB type-approved equipment and get the vendor’s site-planning guide.
- Prepare layouts and shielding calculations, then file on eLORA (institute registration, equipment declaration and RSO).
- File PCPNDT registration for ultrasound before the machine is installed.
- Complete civil works, shielding, HVAC, electrical and IT.
- Install equipment, run QA tests, and obtain the AERB licence or registration.
- Recruit and train staff, issue TLD badges, and set up the Form F and record-keeping process.
- Go live with PACS/RIS, referral partnerships and insurer empanelment.
Frequently asked questions
Do I need an AERB licence for an MRI machine?
No. MRI does not use ionising radiation, so it is not licensed by AERB. You still need clinical establishment registration, fire and local approvals, and careful engineering for the RF cage, quench pipe, magnetic field zoning and floor loading.
What is the minimum room size for an X-ray or CT room?
AERB's earlier code set at least 18 square metres for a general X-ray room and at least 25 square metres for a CT gantry room, with no side shorter than 4 metres. The current code requires an appropriate area and provides model layouts, and most planners still use the older figures as practical minimums.
Is a Radiological Safety Officer mandatory for a CT scan centre?
Yes. For CT and interventional radiology, AERB requires an approved Radiological Safety Officer to be available, and RSO approval is needed before applying for the licence through eLORA.
How long is PCPNDT registration valid?
PCPNDT registration for an ultrasound facility is valid for five years and must be renewed before expiry. The certificate must be displayed, and Form F must be completed for every pregnant woman scanned.
Can I buy a refurbished CT scanner in India?
Refurbished CT systems are widely used to reduce capital cost, but the model must be AERB type-approved and supplied, installed and serviced by AERB-authorised agencies. Insist on a warranty, a clear tube history and an annual maintenance contract.
Plan your imaging centre with Hospertz
Modality planning, AERB-ready layouts, shielding, MEP, equipment procurement and licensing, all coordinated by one team.
Keep reading
Cost figures are indicative 2026 planning ranges, not quotations. AERB and PCPNDT requirements are updated from time to time, so always check eLORA and your district Appropriate Authority for the current rules before you apply.
Get an AERB-ready layout and approvals roadmap from our planning team.
Free consultationWhatsApp us